SNESFASSetNumberSmoothDown
Sets the number of pre-smoothing steps to use on all levels.
Synopsis
#include "petscsnes.h"
PetscErrorCode
SNESFASSetNumberSmoothDown
(
SNES
snes,
PetscInt
n)
Logically Collective on
SNES
Input Parameters
snes
- the multigrid context
n
- the number of smoothing steps
Options Database Key
-snes_fas_smoothdown <n>
-Sets number of pre-smoothing steps