petsc-3.13.6 2020-09-29
Report Typos and Errors

SNESFASSetNumberSmoothDown

Sets the number of pre-smoothing steps to use on all levels.

Synopsis

#include "petscsnes.h"  
PetscErrorCode SNESFASSetNumberSmoothDown(SNES snes, PetscInt n)
Logically Collective on SNES

Input Parameters

snes - the multigrid context
n - the number of smoothing steps

Options Database Key

-snes_fas_smoothdown <n> -Sets number of pre-smoothing steps

See Also

SNESFASSetNumberSmoothUp()

Level

advanced

Location

src/snes/impls/fas/fasfunc.c
Index of all SNESFAS routines
Table of Contents for all manual pages
Index of all manual pages